~33.33 sq ft per bundle; 3 bundles per square (per GAF line)

Key features
StainGuard Plus algae protection on eligible packages (per GAF)
LayerLock with StrikeZone; UL 2218 Class 3 for HDZ line (per GAF)
Technical specifications
| Thickness | 2.4 in |
|---|---|
| Width | 13.25 in |
| Length | 39.375 in |
| Coverage | 33.33 sq ft/pack |
| Material | Fiberglass-reinforced asphalt architectural laminate |
| Fire rating | UL Class A fire classification (ANSI/UL 790) per GAF Timberline HDZ line documentation |
| Construction type | Laminated architectural strip shingle (Timberline HDZ High Definition) |
| Application area | Steep-slope asphalt shingle roof systems installed per GAF requirements; WindProven limited wind warranty requires qualifying GAF accessory system |
Product details
Mission Brown reads deeper than mid-tone neutrals, which helps traditional brick and stone elevations feel grounded without jumping to near-black charcoal caps.
Within Timberline HDZ, the product story is still the laminated architectural platform documented on the HDZ specification sheet, including line-level UL Class A fire classification and UL 2218 Class 3 impact resistance language.
Bundle math for HDZ is commonly quoted around 33.33 square feet per bundle with three bundles per square; use that as a planning anchor, then reconcile to bundle text and site measurements before purchasing.
Algae-resistant labeling matters for merchandising and homeowner confidence; StainGuard Plus-related warranty content applies to eligible packages as described in GAF warranty literature, not inferred from color names alone.
Installation discipline is where contractors earn margin: straight lines, consistent exposures, and careful handling around hips and ridges reduce rework and callback risk.
LayerLock and StrikeZone are line features; they support training and QC narratives, but they do not replace correct flashing sequence or compatible underlayment selection.
For coastal or high-wind jurisdictions, escalate beyond marketing copy to the manufacturer’s wind-related installation instructions and any locally required product approval listings applicable to the project.
Documents & certifications
Technical data sheet
Manufacturer-tested R-value, coverage, fire notes, and handling—use for submittals, RFIs, and field QA.
Download PDF (opens in new tab)Certifications & compliance
UL 790 Class A fire; UL 2218 Class 3 impact resistance; ASTM D3462, D7158, D3161, D3018 Type I (per manufacturer spec sheet for Timberline HDZ line)