R-30 at 7.25 in. for wood 24 OC module (23 in. × 47 in.) per USA TDS (05-2025)

Key features
Semi-rigid batts with flexible long edges for cavity contact in wide bays
Noncombustible stone wool; 0/0 ASTM E84 per manufacturer TDS
Technical specifications
| R-Value | 30.0 |
|---|---|
| Thickness | 7.25 in |
| Width | 23.0 in |
| Length | 47.0 in |
| Coverage | 30.03 sq ft/pack |
| Material | Stone wool (basalt and recycled steel slag) |
| Fire rating | Noncombustible per ASTM E136; Flame Spread 0 / Smoke Developed 0 per ASTM E84 on ROCKWOOL USA Comfortbatt TDS (05-2025). |
| Sound rating | Thick stone wool improves cavity damping versus minimum fills; STC/NIC still require assembly design and perimeter seals. |
| Density | >1.8 lb/ft³ per ASTM C167 on ROCKWOOL USA Comfortbatt TDS (05-2025). |
| Framing width | 24 in. on-center wood stud module (23 in. batt width per USA TDS) |
| Construction type | Wood stud framing |
| Application area | Attic and cathedral ceilings, high-R exterior wood walls at 24 in. o.c., and exposed floors per ROCKWOOL when 7.25 in. thickness and the 23 in. × 47 in. module fit the cavity. |
Product details
Twenty-four-inch stud spacing saves lumber when the structural path allows it, but wide bays punish wrong-width batts with voids, compression folds, and thermal leakage at the face layer. ROCKWOOL publishes a 23 in. × 47 in. Comfortbatt module paired with R-30 performance at 7.25 in. labeled thickness for wood studs at 24 in. on center on the USA technical data sheet (05-2025).
This SKU (169102) packages that geometry for procurement teams who order by distributor stock numbers rather than RXCB-style callouts. Expect roughly 30.03 sq ft per bag under published YEARS data; confirm on the master label at delivery.
Stone wool’s reaction-to-fire story—ASTM E136 noncombustible and ASTM E84 0/0 indices on the Comfortbatt sheet—is a recurring specifier motivation when assemblies must avoid combustible cavity media.
Density is listed as greater than 1.8 lb/ft³ per ASTM C167 on the same TDS; STC and NIC outcomes remain assembly-dependent, so pair batts with gypsum schedules, seals, and openings your acoustic consultant models.
Seven-and-one-quarter-inch batts do not belong in 3.5 in. 2×4 cavities at full thickness; use them only where the framing depth and energy model accept the full labeled thickness.
Attach https://www.rockwool.com/siteassets/o2-rockwool/documentation/technical-data-sheets/residential/comfortbatt-exterior-wood-and-steel-stud-thermal-batt-insulation-techdata-us.pdf (05-2025 issuance) to submittals and refresh when superseded; use https://www.rockwool.com/north-america/products-and-applications/products/comfortbatt for marketing context and accessory documents.
Documents & certifications
Technical data sheet
Manufacturer-tested R-value, coverage, fire notes, and handling—use for submittals, RFIs, and field QA.
Download PDF (opens in new tab)Certifications & compliance
ASTM C665 Type I compliant, ASTM E136 noncombustible, ASTM E84 flame spread 0 / smoke developed 0 (Note 1 Class A per IBC on TDS), ASTM C518 thermal resistance per published R-thickness table, GREENGUARD Gold per ROCKWOOL Comfortbatt marketing