UL Type FC30 edge marking for inspector verification per USG

Key features
Lighter 1.7 lb/sq ft nominal panel than standard 2.2 lb/sq ft Firecode X per USG data
Twelve-foot module for tall interiors when FC30-listed designs apply
Technical specifications
| R-Value | 0.56 |
|---|---|
| Thickness | 0.625 in |
| Width | 48.0 in |
| Length | 144.0 in |
| Coverage | 48.0 sq ft/pack |
| Material | Innovative noncombustible gypsum core with recycled papers—EcoSmart Firecode 30 composite per USG |
| Fire rating | 5/8 in. panel (UL Type FC30) per USG EcoSmart Firecode 30; USG states ASTM C1396 scope includes non-Type X gypsum wallboard for this product while UL classifies fire resistance for listed assemblies—match the published UL design to FC30, not generic Type X assumptions. |
| Sound rating | Acoustic performance is assembly-dependent; gypsum finish layers contribute to STC in tested partition assemblies (ASTM E90). |
| Density | Nominal 1.7 lb/sq ft per USG EcoSmart Firecode 30 specifications |
| Construction type | ASTM C1396 5/8 in. gypsum wallboard scope per USG EcoSmart Firecode 30 (USG states non-Type X classification in product overview) |
| Application area | Interior wall and ceiling assemblies where UL designs list FC30 panels; not automatically interchangeable with SCX or ULIX Type X per USG |
Product details
EcoSmart Firecode 30 addresses assemblies that call for UL Type FC30—not generic Type X language: USG’s overview ties ASTM C1396 to five-eighths gypsum wallboard while clarifying non-Type X classification in the product story, even though UL still classifies FC30 for specific fire-resistance-rated designs.
Twelve-foot sheets cover forty-eight square feet; at 1.7 lb per square foot nominal per USG, plan near eighty-two pounds per sheet—lighter than standard SCX planning weights but not automatically interchangeable layer-for-layer.
GREENGUARD Gold, biobased/recycled positioning, and printed FC30 edge marks belong in sustainability and inspection checklists alike; photograph stamps before cover-up on contentious jobs.
Do not use FC30 in a shower wet wall without a system detail—USG lists Moisture Resistance: No on this product page; wet areas need membrane and backer strategies from TCNA-aligned documentation.
Estimators comparing truck weights should document FC30 versus SCX versus ULIX densities separately; accidental bundle mixing voids both safety plans and UL compliance.
Documents & certifications
Technical data sheet
Manufacturer-tested R-value, coverage, fire notes, and handling—use for submittals, RFIs, and field QA.
Download PDF (opens in new tab)Certifications & compliance
GREENGUARD Gold; UL fire-resistance classification (30-minute and 1-hour walls referenced by USG); biobased/recycled claims per USG