Twelve-foot SCX module for tall rated elevations when designs allow

Key features
Standard Firecode X weight class for familiar crane and stocking math per USG
Tapered edges compatible with Sheetrock joint treatment per USG
Technical specifications
| R-Value | 0.56 |
|---|---|
| Thickness | 0.625 in |
| Width | 48.0 in |
| Length | 144.0 in |
| Coverage | 48.0 sq ft/pack |
| Material | Noncombustible gypsum core with recycled face and back papers (Firecode X per USG) |
| Fire rating | 5/8 in. Type X gypsum panel (UL Type SCX) per USG Firecode X; UL Classified for fire resistance where SCX is listed; edge marking on long edge per USG. |
| Sound rating | Acoustic performance is assembly-dependent; gypsum finish layers contribute to STC in tested partition assemblies (ASTM E90). |
| Density | Nominal 2.2 lb/sq ft per USG Firecode X specifications |
| Construction type | ASTM C1396 for 5/8 in. Type X gypsum wallboard per USG Firecode X |
| Application area | Rated interior walls and ceilings where UL-listed SCX layers are specified |
Product details
Twelve-foot Firecode X is the tall-wall option when logistics and UL listings align: fewer horizontal joints can accelerate rated shaft production, but door heights, hoist beams, and temporary protection must prove out before committing trucks.
Forty-eight square feet at USG’s 2.2 lb per square foot nominal lands near 106 pounds per sheet—recalculate staging loads when bundles stack three high on a deck.
Inspector traceability depends on SCX edge printing; photograph bundles during receiving if disputes arise about swapped loads from the yard.
GREENGUARD Gold and ASTM C1396 Type X language support school and healthcare submittals where low-emitting documentation rides alongside fire ratings.
Never substitute EcoSmart ULIX or FC30 panels purely to save weight unless the UL book explicitly permits it—post-install discovery is catastrophically expensive.
Documents & certifications
Technical data sheet
Manufacturer-tested R-value, coverage, fire notes, and handling—use for submittals, RFIs, and field QA.
Download PDF (opens in new tab)Certifications & compliance
GREENGUARD Gold; UL fire and surface-burning classification per USG; ASTM C1396 Type X