Lightweight Mold Tough line at 1.35 lb/sq ft nominal density per USG

Key features
Moisture- and mold-resistant papers with moisture-resistant gypsum core per USG
Twelve-foot module to reduce horizontal joints on compatible wall heights
Technical specifications
| R-Value | 0.45 |
|---|---|
| Thickness | 0.5 in |
| Width | 48.0 in |
| Length | 144.0 in |
| Coverage | 48.0 sq ft/pack |
| Material | Moisture-resistant gypsum core with moisture- and mold-resistant recycled papers (UltraLight Mold Tough per USG) |
| Fire rating | Noncombustible gypsum core per typical gypsum-board listings; UL classification for surface-burning characteristics and noncombustibility per USG. Not a Type X (firecode) panel unless a separate Type X SKU is specified—verify UL design listings for rated assemblies. |
| Sound rating | Acoustic performance is assembly-dependent; gypsum finish layers contribute to STC in tested partition assemblies (ASTM E90). |
| Density | Nominal 1.35 lb/sq ft panel weight per USG Mold Tough UltraLight specifications |
| Construction type | ASTM C1396 for 1/2 in. water-resistant gypsum wallboard and related categories per USG Mold Tough UltraLight |
| Application area | Interior walls and ceilings where enhanced moisture and mold resistance is desired; follow USG installation guidance |
Product details
Twelve-foot Mold Tough is the seam-minimization play for tall, humidity-adjacent walls—think hotel wet walls, locker corridors, or tall utility chases—provided your crew can protect long edges through the building.
Forty-eight square feet per sheet at 1.35 lb per square foot nominal lands near sixty-five pounds nominal per USG—coordinate team lifts, corner guards, and laydown areas before the boom truck leaves.
The Mold Tough UltraLight certification bundle—ASTM C1396 water-resistant scope, ASTM D3273 references, UL classification, GREENGUARD Gold—should be copied into LEED-adjacent or school packages where low-emitting documentation is graded.
Do not confuse Mold Tough with a shower waterproofing layer; direct-spray zones still need assemblies proven for continuous water exposure.
For rated lines, edge-printed UL types must match the drawing schedule—never cover long panels until the inspector has confirmed the marking if the contract requires it.
Documents & certifications
Technical data sheet
Manufacturer-tested R-value, coverage, fire notes, and handling—use for submittals, RFIs, and field QA.
Download PDF (opens in new tab)Certifications & compliance
GREENGUARD Gold; UL classification (surface burning / noncombustibility per USG); ASTM C1396; ASTM D3273 mold-surface test per USG