93 in. length aligned with common pre-cut stud and modular wall workflows

Key features
Kraft facing for code-coordinated vapor retarder placement when details allow
R-15 labeled performance in a 3.5 in. thick batt for 2×4 cavities
Technical specifications
| R-Value | 15.0 |
|---|---|
| Thickness | 3.5 in |
| Width | 15.0 in |
| Length | 93.0 in |
| Coverage | 67.81 sq ft/pack |
| Material | Fiberglass (PINK Next Gen), kraft-faced |
| Fire rating | ASTM C665; glass fibers ASTM E136 noncombustible when unfaced. Kraft facing is combustible—orient facing per IECC, IRC, and local amendments; kraft-faced PINK Next Gen acceptable ICC construction types III, IV, and V per OC literature. |
| Sound rating | Cavity-fill fiberglass improves typical wall STC versus an empty cavity; assembly STC depends on studs, layers, and openings. |
| Density | Light-density flexible batt per ASTM C665 manufacturer listings; see TDS for product-specific values. |
| Thermal conductivity | See manufacturer TDS (ASTM C518) for tested thermal conductivity at labeled R-value. |
| Framing width | 15 in. width for 16 in. on-center stud spacing in nominal 2×4 walls. |
| Construction type | Wood-frame and light-gauge metal-frame cavity construction |
| Application area | Wood- and metal-framed walls, floors, roof/ceilings; interior side of basement and unvented crawlspace walls per code and OC literature. |
Product details
About 67.81 square feet per package (IDI-listed coverage). Primary use: nominal 2×4 exterior and partition walls on 16 in. on-center framing where the specifier selects kraft-faced R-15 cavity fill and wants 93 in. batt lengths aligned with commercial pre-cut stud workflows and modular eight-foot-ish wall heights.
ME21 packages PINK Next Gen Fiberglas at 3.5 in. labeled thickness for R-15 performance, 15 in. width for the common 14-1/2 in. clear bay, and 93 in. length as the distributor-listed module. Kraft facing supports Class I vapor-retarder detailing when oriented per code—pair disciplined cavity fit with continuous air barrier work at rim, sill, and penetration clusters.
From a building science perspective, kraft is not a substitute for air sealing; it is a vapor-control layer that must agree with your climate zone, exterior foam strategy, and interior finish sequence.
Manufactured to ASTM C665; glass fibers are treated as noncombustible per ASTM E136 when unfaced in manufacturer documentation, while kraft facing is combustible—follow OC guidance for protection and hot-work rules. Kraft-faced PINK Next Gen is listed for ICC construction types III, IV, and V when used as documented. GREENGUARD certification with formaldehyde-free validation and a UL Environment EPD support typical submittals.
Commercial corridors and TI projects often standardize on 93 in. packs because they match pre-cut stud ordering; still verify plate lines after slab tolerance before locking truck counts.
Submittal discipline: keep the distributor-listed dimensions (3.5 in. × 15.0 in. × 93.0 in.) and about 67.81 square feet per package attached to the same SKU on purchase orders, delivery tickets, and photos for QA. Authoritative tested language and code-oriented statements belong in the current manufacturer technical data sheet at https://www.idi-insulation.com/media/pdfresources/1004362_data_sheet.pdf.
Documents & certifications
Technical data sheet
Manufacturer-tested R-value, coverage, fire notes, and handling—use for submittals, RFIs, and field QA.
Download PDF (opens in new tab)Certifications & compliance
GREENGUARD (formaldehyde-free validated), UL Environment EPD, California Title 24 Article 3 insulating materials