Unfaced R-19 at 6.5 × 15 × 93 in. per IDI for designer-led vapor detailing

Key features
GREENGUARD Gold called out on the IDI product listing for submittals
93 in. length for commercial pre-cut stud stacks and modular wall heights
Technical specifications
| R-Value | 19.0 |
|---|---|
| Thickness | 6.5 in |
| Width | 15.0 in |
| Length | 93.0 in |
| Coverage | 77.5 sq ft/pack |
| Material | Fiberglass (PINK Next Gen), unfaced |
| Fire rating | ASTM C665; unfaced glass fibers classified noncombustible per ASTM E136 in manufacturer documentation. Unfaced PINK Next Gen acceptable ICC construction types I through V when installed per Owens Corning literature. |
| Sound rating | Cavity-fill fiberglass improves typical assembly STC versus an empty cavity; final acoustic performance is assembly-dependent. |
| Density | Light-density flexible batt per ASTM C665 manufacturer listings; see TDS for product-specific values. |
| Thermal conductivity | Nominal R-value at labeled thickness; see manufacturer TDS (ASTM C518) for tested conductivity. |
| Framing width | 15 in. width for 16 in. on-center stud spacing in nominal 2×6 walls |
| Construction type | Wood-frame and light-gauge metal-frame cavity construction |
| Application area | Wood- and metal-framed walls, floors, and roof/ceilings; interior side of basement and unvented crawlspace walls per code and Owens Corning literature. |
Product details
About 77.5 square feet per package (IDI-listed coverage). Primary use: nominal 2×6 walls, floors, and ceilings on 16 in. on-center framing where R-19 unfaced cavity fill is specified and 93 in. lengths match pre-cut stud ordering.
E55 lists 6.5 in. labeled thickness, 15 in. width, and 93 in. length on IDI Insulation—the geometry mirrors E61’s listed module but removes factory kraft so vapor control can be executed with smart membranes, poly, or exterior continuous insulation as the energy designer directs.
IDI markets GREENGUARD Gold certification and Next Gen handling benefits for this listing. Field teams should still emphasize full labeled thickness, continuous air barriers at rim and penetrations, and careful relief at outlets and pipes because compressed fiberglass under-performs in models and in reality.
Use the PINK Next Gen Fiberglas insulation product data sheet linked from IDI for authoritative tested properties. When estimators compare E55 to M47, remember M47 is 16 × 96 in. with different coverage—never swap square-foot constants between item numbers on the same takeoff sheet.
Documents & certifications
Technical data sheet
Manufacturer-tested R-value, coverage, fire notes, and handling—use for submittals, RFIs, and field QA.
Download PDF (opens in new tab)Certifications & compliance
GREENGUARD Gold certified per IDI product listing; UL Environment EPD per manufacturer family documentation; California Title 24 Article 3 insulating materials where applicable.